Fluctuation scaling, the calibration of dispersion, and the detection of differences
Abstract
Fluctuation scaling describes the relationship between the mean and standard deviation of a set of measurements. An example is Horwitz scaling which has been reported from inter-laboratory studies. Horwitz and similar studies have reported simple exponential and segmented scaling laws with exponents (α) typically between 0.85 (Horwitz) and 1 when not operating near a detection limit. When approaching a detection limit the exponents change and approach an apparently Gaussian (α = 0) model. This behavior is generally presented as a property of inter-laboratory studies which makes controlled replication to understand the behavior costly to perform. To assess the contribution of instrumentation to larger scale fluctuation scaling, we measured the behavior of two inductively coupled plasma atomic emission spectrometry (ICP-AES) systems, in two laboratories measuring thulium using 2 emission lines. The standard deviation universally increased with the uncalibrated signal indicating the system was heteroscedastic. The response from all lines and both instruments was consistent with a single exponential dispersion model having parameters α = 1.09 and β = 0.0035. No evidence of Horwitz scaling was found and there was no evidence of Poisson noise limiting behavior. The “Gaussian” component was a consequence of background subtraction for all lines and both instruments. The observation of a simple exponential dispersion model in the data allows for the definition of a difference detection limit (DDL) with universal applicability to systems following known dispersion. The DDL is the minimum separation between two points along a dispersion model required to claim they are different according to a particular statistical test. The DDL scales transparently with the mean and works at any location in a response function.Citation
Holland R., Rebmann R., Williams C., Hanley QS. (2017) 'Fluctuation Scaling, the Calibration of Dispersion, and the Detection of Differences', Analytical Chemistry, 89(21) p. 11568-11575. doi: 10.1021/acs.analchem.7b02909Publisher
ACS PublicationsJournal
Analytical ChemistryAdditional Links
http://pubs.acs.org/doi/abs/10.1021/acs.analchem.7b02909Type
Journal articleLanguage
enDescription
This is an accepted manuscript of an article published by American Chemical Society in Analytical Chemistry on 11/10/2017, available online: https://doi.org/10.1021/acs.analchem.7b02909 The accepted version of the publication may differ from the final published version.ISSN
0003-2700ae974a485f413a2113503eed53cd6c53
10.1021/acs.analchem.7b02909
Scopus Count
Collections
The following licence applies to the copyright and re-use of this item:
- Creative Commons
Except where otherwise noted, this item's license is described as https://creativecommons.org/CC BY-NC-ND 4.0