    The development of a high intensity dance performance fitness test.

    • CSV
    • RefMan
    • EndNote
    • BibTex
    • RefWorks
    Authors
    Wyon, Matthew A.
    Weller, Peter
    Ehrenberg, Shantel
    Irvine, Sarah
    Quin, Edel
    Rafferty, Sonia
    Redding, Emma
    Cox, Carol
    Issue Date
    2009
    
    Metadata
    Show full item record
    Abstract
    While there is currently a validated dance-specific exercise method of measuring aerobic fitness, no such test has been developed to measure high intensity capabilities in dance. The purpose of this study was to initiate an intermittent high intensity dance-specific fitness test. The test was designed to be able to observe changes in heart rate (HR), thereby allowing for a measurement of physical fitness at high intensities. Sixteen professional dancers (4 males and 12 females) volunteered to take part in this study. The fitness test protocol consists of movements that are representative of contemporary dance, and contains exercise and rest periods that mimic the intermittent nature of dance. The participants performed four trials. The physiological variables measured were HR (b.min(-1)) for each one minute bout of the four minute test for all trials, oxygen uptake (VO(2)) throughout the test, and end blood lactate (BLa mmol.L) for each trial. In addition, five of the participants undertook a maximal oxygen uptake treadmill test, and the scores obtained were compared with those from the dance test. Results show HR consistency across each one minute bout of the test and across each of the four trials of testing for all participants, indicating that the test is reliable. There was good reliability between bouts of each trial (typical error as % of CV = 1.5), intraclass "r" = 0.8, and good reliability between the four trials (typical error as % of CV = 2.1), intraclass "r" = 0.82. There were no significant differences between the maximal VO(2) and BLa scores established in the treadmill and dance tests, demonstrating validity. Thus, the results of this study indicate that the high intensity dance-specific test is a reliable and valid means of assessing and monitoring the cardiovascular fitness of dancers. The test allows dancers to be assessed within an environment that they are accustomed to (the studio), using a mode of exercise that is relevant (dance), and it is of adequate intensity to be representative of performance.
    Citation
    The development of a high intensity dance performance fitness test. 2009, 13 (1):3-9 J Dance Med Sci
    Journal
    Journal of dance medicine & science : official publication of the International Association for Dance Medicine & Science
    URI
    http://hdl.handle.net/2436/313628
    PubMed ID
    19416609
    Type
    Journal article
    Language
    en
    ISSN
    1089-313X
    Collections
    Faculty of Education, Health and Wellbeing

    entitlement

    Related articles

    • Aerobic demands of the dance simulation game.
    • Authors: Tan B, Aziz AR, Chua K, Teh KC
    • Issue date: 2002 Feb
    • Reliability and validity of three fitness tests for adults with mental handicaps.
    • Authors: Montgomery DL, Reid G, Koziris LP
    • Issue date: 1992 Dec
    • A test to estimate VO2max in females using aerobic dance, heart rate, BMI, and age.
    • Authors: Olson MS, Williford HN, Blessing DL, Wilson GD, Halpin G
    • Issue date: 1995 Sep
    • Influence of cardiopulmonary exercise testing protocol and resting VO(2) assessment on %HR(max), %HRR, %VO(2max) and %VO(2)R relationships.
    • Authors: Cunha FA, Midgley AW, Monteiro WD, Farinatti PT
    • Issue date: 2010 May
    • Development of the Dance Fitness Indicator©: A High-Intensity Dance Fitness Test: A Preliminary Study.
    • Authors: Rogan K, Wyon M
    • Issue date: 2022 Mar
    DSpace software (copyright © 2002 - 2023)  DuraSpace
    Quick Guide | Contact Us
    Open Repository is a service operated by 
    Atmire NV
     

    Export search results

    The export option will allow you to export the current search results of the entered query to a file. Different formats are available for download. To export the items, click on the button corresponding with the preferred download format.

    By default, clicking on the export buttons will result in a download of the allowed maximum amount of items.

    To select a subset of the search results, click "Selective Export" button and make a selection of the items you want to export. The amount of items that can be exported at once is similarly restricted as the full export.

    After making a selection, click one of the export format buttons. The amount of items that will be exported is indicated in the bubble next to export format.